Updated on March 8, 2024

·

Created on August 31, 2021

Laerdal Servi Ventilator

Upcoming Update

The Laerdal Servi Ventilator is an emergency invasive ventilator designed and implemented in response to the COVID-19 pandemic. Courtesy of WHO Compen

Tested By
  • Norwegian Defense Research Establishment (FFI)
Content Partners
Unknown

Author

Product Description

Developed in 2020 in response to the needs from the global COVID-19 pandemic, the Laerdal Servi Ventilator is an emergency invasive ventilator designed not to replace existing ventilators in over-capacity hospitals, but to offer a supplemental technology in emergency situations. As such, the design features settings for sedated patients with respiratory failure, intended to be used over a relatively short period of time on the patient.

This product was selected for inclusion in WHO’s 2021 Compendium of Innovative Health Technologies for Low‐Resource Settings.

Target SDGs

SDG 3: Good Health and Well-Being

Target Users (Target Impact Group)

Small and Medium-sized Enterprises, Public Sector Agencies

Distributors / Implementing Organizations

This product was implemented by the following organizations: the Norwegian Defense Research Establishment, Edge Health Technologies AS, Laerdal Medical AS, and Servi AS.

Competitive Landscape

Direct competitors include Gradian Comprehensive Care Ventilator (CCV).

Manufacturing/Building Method

The product is manufactured by Laerdal in Stavanger, Norway. The company produces components and and other products from their factories in Norway, Mexico, China, and USA.

Intellectural Property Type

Select Type

User Provision Model

The emergency ventilators are purchased by European governments to then distribute to hospitals in need.

Distributions to Date Status

1000 ventilators as of 2020

Design Specifications

The Laerdal Servi Ventilator incorporates the following components: (1) oxygen tubing and reservoir kit, (2) three 28 cm extension tubes, (3) patient valve with pressure relief valve, (4) exhalation port with a diameter of 30 mm, and (5) manometer connector. There are three consumables: (6) HME filter, (7) Thomas Tube holder, and (8) adjustable PEEP valve. The control unit allows for tidal volume adjustment between 100-800 ml and ventilation rates between 5-30 per min.

Product Schematics

Technical Support

Technical support is provided by the manufacturer.

Replacement Components

Replacement components and consumables are available for purchase from the manufacturer

Lifecycle

Unknown

Manufacturer Specified Performance Parameters

The manufacturer's goal of the rapid-development project emphasized quick production, simple to use, and simplified (but accurate) automated assisted breathing.

Vetted Performance Status

The system has been tested with test lungs to in both controlled and assisted ventilation mode, details of the performance testing and design iterations are available in the FFI report.

Safety

The product has been designed and tested to meet patient safety standards in Norway.

Complementary Technical Systems

None

Compliance with regulations

Received the European CE (Communauté Européenne) Mark

Evaluation methods

Unknown

Other Information

None

Leave a Reply

Explore similar solutions

Agriculture

November 22, 2023

Laerdal Upright Newborn Bag-Mask

Read Solution

Implemented by

Laerdal Global Health

Agriculture

March 8, 2024

Impala Ventilator

Read Solution

Implemented by

MTTS

Agriculture

March 8, 2024

MVM Ventilator

Read Solution

Implemented by

Mechanical Ventilator Milano

Agriculture

March 8, 2024

CERN HEV Ventilator

Read Solution

Implemented by

Conseil Européen pour la Recherche Nucléaire (CERN)

Agriculture

November 22, 2023

Diamedica Helix Portable Ventilator

Read Solution

Implemented by

Diamedica

Agriculture

February 2, 2024

Gradian Comprehensive Care Ventilator (CCV)

Read Solution

Implemented by

Gradian Health Systems

Agriculture

March 6, 2024

iSAVE

Read Solution

Implemented by

Project Prana Foundation

Agriculture

February 5, 2024

Prepex Circumcision Device

Read Solution

Implemented by

Circ MedTech

Agriculture

November 22, 2023

Integrated Resuscitation Systems

Read Solution

Implemented by

GE (General Electric)

Agriculture

March 8, 2024

O2 Cube

Read Solution

Implemented by

Lean Med

All Solutions

Contribute to E4C's Library of Breakthrough Sustainable Development Technology Solutions

Suggest A Solution

Get more information about Solutions Library and its features.

Learn More

Have thoughts on how we can improve?

Give Us Feedback

Join a global community of changemakers.

Become A Member